home *** CD-ROM | disk | FTP | other *** search
/ The Hacker Chronicles - A…the Computer Underground / The Hacker Chronicles - A Tour of the Computer Underground (P-80 Systems).iso / pyro / miltexpl.txt < prev    next >
Text File  |  1992-03-03  |  5KB  |  108 lines

  1. Military Explosives
  2. Part One
  3.  
  4.  
  5. Definitions
  6.  
  7. Military Demolition:
  8. Military demolition is the destruction by fire, water, explosive, mechanical,
  9. or other means of area structures, facilities, or materials to accomplish a
  10. military objective.  Demolitions are explosives used for such purposes.
  11. Demolitions have offensive and defensive uses.  Examples are the removal of
  12. enemy barriers to facilitate the advance and the construction of friendly
  13. barriers to delay or restrict enemy movement.
  14.  
  15. Explosives:
  16. Explosives are substances that, through chemical reaction, violently change to
  17. a gaseous form.  In doing so, they release pressure and heat equally in all
  18. directions.  They are classified as low or high according to the detonating
  19. velocity or speed (in meters or feet per second) at which this change takes
  20. place and other characteristics such as their shattering effect.
  21.  
  22. Low Explosives:
  23. Low explosives change from a solid to a gaseous state slowly aver a sustained
  24. period (up to 400 meters or 1,300 feet per second).  This characteristic makes
  25. low explosives ideal when a pushing or shoving effect is required.  Examples of
  26. low explosives are smokeless and black powders.
  27.  
  28. High Explosives:
  29. High explosives change to a gaseous state almost instantaneously at 1,000
  30. meters per second (3,280 feet per second) to 8,500 meters per second
  31. (27,888 feet per second), producing a shattering effect on the target.
  32. Use high explosives when a shattering effect, or brisance, is required.
  33.  
  34. Relative Effectives (RE) Factor:
  35. Explosives vary in detonating rate or velocity (meters or feet per second), as
  36. well as other characteristics, such as density and energy production.
  37. These characteristics determine their effectiveness for cutting, breaching, or
  38. cratering charges.  Most military demolitions involve cutting or breaching.
  39. The amount of explosive used is adjusted by a relative effectiveness (RE)
  40. factor, which is based upon the shattering effect of the explosive in relation
  41. to that of trinitrotoluene (TNT).  The shattering effect of a high explosive is
  42. related to its detonating velocity.  For example, TNT with a detonating
  43. velocity of 6,900 meters per second has a relative effectiveness factor of
  44. 1.00, while Composition C4 with a detonating velocity of 8,040 meters per
  45. second has a relative effectiveness factor of 1.34.
  46.  
  47. Cratering Effect:
  48. The cratering effect of high explosives depends upon their total energy
  49. content, which determines the amount of energy available to throw the broken
  50. material from the crater.  Because a shattering effect is not required to form
  51. a crater, low-velocity explosives are generally more effective for cratering
  52. purposes.  Therefore, the relative effectiveness factor is not considered in
  53. determining the effect of a cratering charge.  Blasting road craters or ditches
  54. normally requires large amounts of explosives.  Because it is effective and
  55. inexpensive, an ammonium nitrate-based cratering charge is used as a standard
  56. cratering charge.
  57.  
  58.  
  59. Characteristics
  60.  
  61. To be suitable for use in military operations, explosives must have certain
  62. properties.  Military explosives must -- Be inexpensive to manufacture and
  63. capable of being produced from readily available raw material.
  64. Be relatively insensitive to shock or friction, yet able to positively detonate
  65. by easily prepared initiators. Have the shattering effect and potential energy
  66. adequate for the purpose. Be stable enough to retain usefulness for a
  67. reasonable time when stored in any climate at temperatures between -80 and +165
  68. degrees Fahrenheit. Have high density (weight per unit of volume).
  69. Be suitable for use under water or in damp climates.
  70. Have minimum toxicity (poisonous effects) when stored, handled, and detonated.
  71. Be a convenient size and shape for packaging, storing, distributing, handling,
  72. and emplacing by troops.
  73. Have high energy output per unit of volume.
  74.  
  75.  
  76. Detonation
  77.  
  78. The detonation or burning of all explosives produces poisonous fumes.
  79. The chemicals used in explosives are poisonous.
  80. Caution personnel against inhaling fumes or ingesting explosives.
  81. When explosives are used in closed areas or underground, allow adequate time
  82. for the fumes to dissipate before investigation.  Control the explosives to
  83. prevent their use, such as burning as a source of heat or cooking, for other
  84. than intended purpose.
  85.  
  86.  
  87. Fire Hazards
  88.  
  89. Explosives contain their own oxidizer.  Burning explosives cannot be
  90. extinguished by smothering or with water.  In fact, smothering will probably
  91. cause and explosion.  Because of the possibility of detonation while explosives
  92. are burning, observe the minimum safe distance.  WARNING: Personnel should not
  93. attempt to extinguish burning explosives without expert advice and assistance.
  94.  
  95.  
  96. Fire Safety Precautions for Transport
  97.  
  98. If fire breaks out in a vehicle transporting explosives, try to stop the
  99. vehicle away form any populated buildings.  Stop traffic in both directions,
  100. and warn drivers, passengers, and occupants of nearby buildings to keep at
  101. least 2,000 feet away.  Inform police and firefighting authorities that the
  102. cargo is explosives.  If a fire involves only the engine, cab, chassis, or
  103. tires, make an effort to put out the fire with fire extinguishers, sand, dirt,
  104. or water.  If the fire spreads to the body or cargo, STOP FIGHTING THE FIRE AND
  105. EVACUATE THE AREA to a distance of at least 2,000 feet.
  106.     
  107. DOWNLOADED FROM P-80 SYSTEMS......
  108.